Technical Specification of Fire Safety System


Product: Fire Safety System

Supply Part: Supply, Warranty, Installation, Testing and Commissioning and integration of the Fire Alarm System mainly consisting of the Fire Alarm Control Panel (FACP), loop driver cards, Repeater Panel, Detectors and associated Testing kit.

Detectors: Detectors shall be Analogue Addressable type and suitable for connection to the control panel via a two-wire loop circuit (class A wiring).

It shall be possible to: Enable, disable or adjust sensitivity of any addressable device through the system keypad or operator terminal and store events in a non-volatile memory and generate system status reports.

Active Repeater Panel and compatible extension cable : r Panel and compatible extension cable Provision shall be made in the Fire alarm main control panel for connecting repeater panel which will be located at a backup location around 500 meters away.

Scope of Installation and commissioning : 1. Installation as per drawings provided by NPCIL, testing & commissioning of 3 Loop Fire Alarm Control Panel with loop driver cards and Repeater Panel, all supplied items viz. addressable Detectors, Isolators, MCPs, Sounders with base plate and hardware accessories on turnkey basis.
2. Laying and termination of 2C x 1.5 Sq.mm FRLS cable (internal cabling between FAS panel and other components) with all necessary accessories like cable compression glands, lugs, ferruling, end termination, cable tags, through existing 25 dia MS conduits or supplied flexible conduits at end portions for all types of detectors and peripherals for connectivity with the FAS panel.
3.Installation of MS conduits in trench / wall including clamping / fixing of conduits (required MS conduit accessories to be provided by the vendor), Laying in MS conduits and termination of the supplied Cable between Repeater panel and Fire alarm Panel.
4. From the nearest available 240 V AC power supply source, the vendor has to extend power supply to the FAS Panel and Repeater panel. The required cabling, casing/capping locally is included in the scope of the vendor.
5. The control panel & repeater panel shall be anchored on wall. All non-conducting metallic parts shall be connected to a Grounding bus at the bottom of panels. The grounding bus shall be connected to the grounding system of the building.



Product: Fire Safety System

Supply Part: Supply, Warranty, Installation, Testing and Commissioning and integration of the Fire Alarm System mainly consisting of the Fire Alarm Control Panel (FACP), loop driver cards, Repeater Panel, Detectors and associated Testing kit.

Detectors: Detectors shall be Analogue Addressable type and suitable for connection to the control panel via a two-wire loop circuit (class A wiring).

It shall be possible to: Enable, disable or adjust sensitivity of any addressable device through the system keypad or operator terminal and store events in a non-volatile memory and generate system status reports.

Active Repeater Panel and compatible extension cable : r Panel and compatible extension cable Provision shall be made in the Fire alarm main control panel for connecting repeater panel which will be located at a backup location around 500 meters away.

Scope of Installation and commissioning : 1. Installation as per drawings provided by NPCIL, testing & commissioning of 3 Loop Fire Alarm Control Panel with loop driver cards and Repeater Panel, all supplied items viz. addressable Detectors, Isolators, MCPs, Sounders with base plate and hardware accessories on turnkey basis.
2. Laying and termination of 2C x 1.5 Sq.mm FRLS cable (internal cabling between FAS panel and other components) with all necessary accessories like cable compression glands, lugs, ferruling, end termination, cable tags, through existing 25 dia MS conduits or supplied flexible conduits at end portions for all types of detectors and peripherals for connectivity with the FAS panel.
3.Installation of MS conduits in trench / wall including clamping / fixing of conduits (required MS conduit accessories to be provided by the vendor), Laying in MS conduits and termination of the supplied Cable between Repeater panel and Fire alarm Panel.
4. From the nearest available 240 V AC power supply source, the vendor has to extend power supply to the FAS Panel and Repeater panel. The required cabling, casing/capping locally is included in the scope of the vendor.
5. The control panel & repeater panel shall be anchored on wall. All non-conducting metallic parts shall be connected to a Grounding bus at the bottom of panels. The grounding bus shall be connected to the grounding system of the building.



 fire alarm system in red and white color

Fire Alarm System

Nitsui India Pvt Ltd offers a range of fire alarm systems that are designed to detect and alert occupants of a building in the event of a fire. Their fire alarm systems are typically made up of smoke detectors, heat detectors, manual call points, control panels, and notification devices such as horns, strobe lights, or speakers. Nitsui fire alarm systems are designed to meet relevant safety standards and regulations, and can be customized to meet specific requirements of the building. They can be integrated with other building systems, such as security systems, to provide a comprehensive safety and security solution. Nitsui India Pvt Ltd's fire alarm systems can be sophisticated and complex, with features such as automatic testing, self-diagnosis, and remote monitoring. They can also be designed to match the aesthetics of the building and can be finished with a range of materials. Overall, Nitsui India Pvt Ltd offers a range of high-quality fire alarm systems that are designed to meet various needs and requirements.

For Enquiry:     +91 8851222862

Fire Hydrant System

The Nitsui Fire Hydrant System is a fire protection system that includes a network of underground pipelines and above-ground equipment such as hydrants and valves. The system is designed to provide a reliable source of water for firefighters in the event of a fire. The Nitsui Fire Hydrant System is manufactured by Nitsui Co., Ltd., a Japanese company that specializes in fire protection systems and equipment. The company has been in the business for more than 50 years and has a reputation for producing high-quality, reliable products. The system typically consists of a water storage tank, a pump, and a network of pipelines that are connected to hydrants located throughout a building or an area. The system is designed to be self-contained and to provide a continuous supply of water to firefighters even if the main water supply is cut off or compromised. The Nitsui Fire Hydrant System is designed to be easy to install and maintain. The system is typically installed during the construction of a building, but it can also be retrofitted to existing buildings. Regular maintenance is essential to ensure that the system is in good working order and ready to respond in the event of a fire. Overall, the Nitsui Fire Hydrant System is a reliable and effective fire protection system that can help to protect people and property from the devastating effects of fire.

For Enquiry:     +91 8851222862
fire hydrant system fixed in factories in red color

 fire extinguisher in red color

Fire Extinguishing & Suppression System

Nitsui Fire Extinguishing & Suppression System is a product line of fire protection systems that are designed and manufactured by Nitsui India Pvt Ltd. These systems are designed to quickly detect and suppress fires before they can cause significant damage or harm to people.

Nitsui offers a variety of fire extinguishing and suppression systems, including:
Water-based systems:These systems use water as the primary extinguishing agent. They can include automatic sprinkler systems, water mist systems, and deluge systems. Nitsui's water-based systems are designed to be highly effective in extinguishing fires involving solid combustibles such as wood and paper.
Foam-based systems: These systems use foam as the primary extinguishing agent. They can be used to suppress fires involving flammable liquids, such as gasoline and oil. Nitsui's foam-based systems are designed to quickly coat and smother fires, reducing the spread of flames and preventing re-ignition.
Gas-based systems: These systems use gases, such as carbon dioxide or clean agents, as the primary extinguishing agent. They are effective in suppressing fires in areas where water-based systems may not be suitable, such as electrical equipment and data centers. Nitsui's gas-based systems are designed to quickly and safely extinguish fires without damaging sensitive equipment.
Powder-based systems: These systems use dry powder as the primary extinguishing agent. They can be used to suppress fires involving flammable liquids, gases, and electrical equipment. Nitsui's powder-based systems are designed to rapidly extinguish fires and prevent re-ignition.

Nitsui Fire Extinguishing & Suppression Systems are designed to be easy to install and maintain. They are typically installed during the construction of a building, but they can also be retrofitted to existing buildings. Regular maintenance and testing are essential to ensure that the system is in good working order and ready to respond in the event of a fire.

For Enquiry:     +91 8851222862

Browse More of Our Products

 Dock Shelter in blue and yellow color

Dock Shelter

A dock shelter is a protective enclosure that is installed around the edges of a loading dock to seal the gap between the dock and a truck or trailer.

Browse More
 motorised sliding gate in black color

Motorised Sliding gate

Nitsui motorized sliding gate is a type of gate that is powered by an electric motor to slide open and closed along a track or railing.

Browse More
grill rolling shutter in front of shopping mall

Grill Rolling Shutter

Nitsui India Pvt Ltd provides high-quality grill rolling shutters that are designed to provide a high level of security.

Browse More
wooden fire rated door in front of fire

Wooden Fire Rated Door

Nitsui Wooden Fire Rated Doors are a type of fire-resistant door that is made from high-quality wood and designed to provide protection against fire and smoke.

Browse More